Sundanzer_System_Sizing
Return to SunDanzer
The "Design Ambient Temperature (F)" is the maximum average weekly temperature that the cabinet is expected to operate in. If during a warm week the daily high is 100F and the daily low is 80F, then the "Design Ambient Temperature" is 90F.
Example: Look at the left side of the chart above. The DCR165 - 5.8 cu. ft. refrigerator at 84F will need 198 watt hours/day to operate. Now go over to the right side of the chart and look under "Watt-Hours/day Energy Use" for the closest number to 198 which is 200. Now move under the number of sun hours per day. Suppose your state has 5 sun hour/day, you will need at least 76 watts of PV (rated) and a 130 Amp hour battery (12v).